Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support

Product Details
Customization: Available
Customized: Non-Customized
Certification: CE, ISO13485
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (15)
  • Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support
  • Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support
  • Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support
  • Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support
  • Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support
  • Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Main Product
  • Certifications
  • Company Profile
  • Our Advantages
  • Warehouse & Container Loading
  • Cooperation Brand
Overview

Basic Info.

Model NO.
KY3000-TPA
Scale
Small
Type
Breathing Apparatus
Stock
Yes
Medical Industry Experience
24years
Medical Device Business Qualification
Yes
After-Sales Service
Whole Using Lifetime
Transport Package
Standard Export Packaging
Specification
Standard Specification
Trademark
KY
Origin
China

Product Description

Product Description

The neonatal/pediatric continuous positive airway pressure breathing support system is a positive pressure breathing support system that uses a nasal mask or nasal congestion to send continuous positive pressure airflow into the airway. Its principle is to use a medical oxygen source as a power source while effectively controlling the maximum Pressure (MAX-P), peak inspiratory pressure (PIP), CPAP/PEEP pressure equipment, suitable for neonates and children with spontaneous breathing, provide continuous positive pressure ventilation support. The device is a manually operated, gas-driven breathing support system.

Product Advantages

1. Controlled peak inspiratory pressure PIP to safely expand the lungs of newborns/children and provide oxygenation;

2. Constant CPAP/PEEP to keep the lungs open during exhalation, thereby avoiding adhesions Damage and maintain functional residual capacity;

Easy to operate with one hand, the operator will not be fatigued by operating the bladder;

4. Respiratory support system, which can replace temporary breathing and resuscitation support;

The operator's experience, training, attention and attention The degree of fatigue will not affect the output pressure;

6.Constant CPAP/PEEP can assist the baby to breathe while being transported or when changing the ventilator tube.

7. It is mainly used as a resuscitation device for newborns and children with a weight ≤ 10 kg in delivery rooms, infant wards and neonatal intensive care units to provide respiratory support.

Technical Parameters

Model

AD3000-TPA

Pressure gauge

-2-10kPa ( -20~100cmH2O)

Pressure limit (MAX-P)

@0-15LPM ≤ 6kPa(60cmH2O)

Peak Inspiratory Pressure ( PIP )

@5-15LPM 0.2-5.7kPa(2-57cmH2O)

CPAP/PEEP

@5-15LPM 0.03-2.3kPa(0.3-23cmH2O)

Working noise

≤ 55dB (A)

Gas source requirements

0.3MPa-0.4MPa capacity greater than 100L

Safety/performance requirements

YY0600.5-2001

Recommended weight range

≤ 10KG

Working and storage environment

-20ºC~50ºC , the relative humidity is up to 90%

Detailed Photos

Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory SupportKy3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory SupportKy3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory SupportKy3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support

Main Product

Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory SupportKy3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support
 

Certifications

Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory SupportKy3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support

 

Company Profile


Global medical device procurement center

Kangyu company, founded in 2004, is a private enterprise specializing in medical equipment, instrument consumables, OEM agent sales and after-sales service. It has three companies: Kangyu international trading company, baokejian medical equipment company and dajianyuan medical equipment company. It is a one-stop wholesale procurement center of global medical devices. Guangzhou has a large exhibition hall and warehouse!
The company's main products: surgical equipment, laboratory equipment, ultrasonic equipment, gynecological equipment, X-ray equipment, treatment and rehabilitation equipment, ophthalmic equipment, ear, nose and throat equipment, stomatology equipment, disinfection and sterilization equipment, first aid equipment, examination and physical examination equipment, pathology equipment, low-temperature refrigeration equipment, pharmaceutical equipment, orthopedic equipment, laboratory equipment, medical beauty instruments, pet animal equipment, There are tens of thousands of laboratory consumables, medical lathes, stainless steel instruments and utensils.


Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support

Our Advantages

 
SKU Over 5,000
Medical Industry experience Over 24Year
Offline store Store with 20 years of experience
Stock in Stock YES
Export customers Over 1,000
After-Sales Service Whole Using Lifetime

Warehouse & Container Loading



Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory SupportKy3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support

Cooperation Brand

Ky3000-Tpa Infant Resuscitator, Neonatal Resuscitator for Temporary Respiratory Support

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More